The custom output command is used to change format of the information
reported from the listener via the command interface. It allows the
user to specify which parameters should be reported. The parameters are
the names of the commands from the tables.
For example, by sending ``P CO DB VR'' over the command interface, the
reports from the listener will look like:
VR=2.0,DB=98
Note: The user cannot specify the order in which the parameter values should be reported.
We provide two special settings:
For example, by sending ``P '' the report of the distance will
look like
VR=2.0,ID=01:dd:be:be:09:00:00:95,SP=MIT-2,DB=224,DR=6479,TM=6789,TS=455424,PC=(0,0,0),TB=2,TP=0
Note: The custom output command works only when the output format is set to 3. The example also assumes that all the options are enabled on the beacon and that the listener can measure distances from the beacon.